Smart Dam Safety Management

01 Drone and LiDAR-Based High-Resolution Terrain Mapping

Integrates drone and LiDAR survey data with national base maps to provide highly detailed terrain information around dams.

  • Effect : Terrain resolution improved fivefold, from 5m to 1m grid spacing

02 Integrated 3D BIM Models and Facility Information

Major dam structures, including dam bodies, spillways, powerhouses, and intake towers, are modeled in 3D BIM, with unique identification codes assigned to individual components.

  • Effect : Digitized over 827,000 pages of paper drawings and reports and links them to 3D models for integrated facility information management.

03 Automated Defect Detection Using Drone Imagery and AI

Drone imagery is processed into orthographic façade images, enabling AI to automatically detect six types of structural defects: (Cracks, Efflorescence, Delamination, Spalling, Exposed Reinforcement, Water Leakage)
Inspection maps and condition assessment reports are also generated automatically.

  • Effect : Inspection time reduced from 100 days to 10 days(90% reduction) and Inspection costs reduced by approximately 95%.

04 Automated Dam Safety Assessment During Earthquakes

Automatically identifies dams within a 50km raius of an earthquake’s epicenter and performs rapid safety assessments using pre-established structural analysis models for each dam.

  • Effect: Assessment time reduced from several days to just a few minutes per dam, enabling 24/7 earthquake response.

05 Dam-Type-Specific Seepage and Internal Condition Mo

Concrete Dams : Surface seepage monitoring using thermal imaging cameras.

  • Embankment Dams(Earthfill and Rockfill) : Internal condition monitoring using electrical resistivity technology to detect potential seepage.
  • Composite Dams : Integrated seepage monitoring combining both technologies to address the characteristics of each dam type.


  • Effect : Seepage monitoring technologies tailored to different dam types were demonstrated at 33 facilities nationwide, establishing a continuous monitoring system for seepage and internal dam conditions.